8-27
8.2.9. Gong/Buzzer PI & voice:
OPTION
DESCRIPTION
UNIT
DM
FIRE RETURN
BUZ.TURN OFF DELAY
Fire buzzer turn off delay. If the fire buzzer
needs to be eared during all the main floor
return, write 9999 in that register.
0.1s
0151
CAR CALL
ACCEPTANCE SIG.
Activation of the car call acceptance Buzzer
pulse. (CCA)
YES/NO
0086
CCA BUZZER SIG.
PULSE DURATION
Car call acceptance pulse duration time.
0.1s
0038
ACTIVATE PASSING
GONG GP
Passing gong activated ? (GP)
YES/NO
0081
ACTIVATE VOCAL
ANNUNCIATOR
In car vocal announcer activated. If NO, the SPE
output will not trig and no messages outputs will
activate.
YES/NO
0093
FL. NAME WHEN
PASSING EACH FLOOR
If = YES, the voice tells the floor name at each
floor during a multiple floor ride.
If = NO, the voice tells the floor name only at
arrival in levelling.
YES/NO
0039
BINARY CODE
INDICATOR ABCDE
If = NO, standard indicator (one light per floor).
There is a timer that turns off the light after 30
min. to avoid burning the light cover
If = YES, binary indicator A, B, C, D.
YES/NO
0126
PI UNDEF. STOP
PERIOD CODE 3-99
If value less than 3 = NO. There is no flashing
code sent to the position indicator when
undefined stop period happened.
If the value is greater than equal to 3 = YES.
That code number is sent to the position
indicator when undefined stop period happened.
When the car moves, the actual position will be
sent to the position indicator.
Undefined stop period is:
Faults , SI, INSPEC. MAINT, Out of service.
n/a
0160
PI DISPLAY CODE
IND/FIRE/INSPECT
That feature when enabled, sends three different
codes to the position indicator on those
situations: Independent service, Fire, Inspection.
When the car moves, the actual position will be
sent to the position indicator.
YES/NO
0160
PI INDEPENDENT
SERVICE CODE3-99
Flashing code to send to the position indicator in
independent service (3 to 99).
n/a
0161
PI FIRE SERVICE CODE
3-99
Flashing code to send to the position indicator
when general fire is activated (3 to 99).
n/a
0162
PI INSPECTION
SERVICE CODE3-99
Flashing code to send to the position indicator in
inspection service (3 to 99).
n/a
0163
Содержание 2000 Series
Страница 1: ...USER S MANUAL HYDRAULIC ELEVATOR CONTROLLER CANBUS PROCESSOR JLL 2000 SERIES VERSION 2 02 000 ...
Страница 2: ......
Страница 5: ......
Страница 17: ...2 1 2 USE OF THE PROGRAMMING CONSOLE PRO01 OU PRO27 Not available ...
Страница 25: ...5 1 5 CONTROLLER TYPE Section not applicable ...
Страница 28: ...6 3 Standard tape selector installation ...
Страница 33: ...6 8 FIG 5 Complete installation of the selector tape and magnetic reader see Fig 6 FIG 6 Plastic guideshoe ...
Страница 44: ...6 19 ...
Страница 47: ...7 22 7 TERMINAL SPEED REDUCING DEVICE FOR ELEVATOR GREATER THAN 50 MIN Section not applicable ...
Страница 60: ...10 2 ...
Страница 72: ...10 14 Alarms Description Causes et verifications supplied Check the door opening ...