P01.28
Time of ending section of
deceleration S curve
0.0
–50.0s
0.1s
P01.29
Short-circuit brake current
0.0
–150.0% (of the rated VFD output
current)
0.0%
P01.30
Hold time of short-circuit
brake at startup
0.00
–50.00s
0.00s
P01.31
Hold time of short-circuit
brake at stop
0.00
–50.00s
0.00s
P01.32
Pre-exciting time of jogging 0
–10.000s
0.000s
P01.33
Starting frequency of braking
for jogging to stop
0
–P00.03
0.00Hz
P01.34
Delay to enter sleep
0
–3600.0s
0.0s
P05.01
–
P05.06
Digital input function
selection
1: Forward running
2: Reverse running
4: Forward jogging
5: Reverse jogging
6: Coast to stop
7: Fault reset
8: Running pause
21: Acceleration/deceleration time
selection 1
22: Acceleration/deceleration time
selection 2
30: Acceleration/deceleration disabled
/
P08.06
Running frequency of jog
0.00Hz
–P00.03 (max. output frequency)
5.00Hz
P08.07
Acceleration time at jogging 0.0
–3600.0s
Depend on
model
P08.08
Deceleration time at jogging 0.0
–3600.0s
Depend on
model
P08.00
Acceleration time 2
0.0
–3600.0s
Depend on
model
P08.01
Declaration time 2
0.0
–3600.0s
Depend on
model
P08.02
Acceleration time 3
0.0
–3600.0s
Depend on
model
P08.03
Declaration time 3
0.0
–3600.0s
Depend on
model
P08.04
Acceleration time 4
0.0
–3600.0s
Depend on
model
P08.05
Declaration time 4
0.0
–3600.0s
Depend on
model