Goodrive350 IP55 High-ingress Protection Series VFD
Function parameter list
-235-
Function
code
Name
Description
Default
value
Modify
limit digital
P28.16
EC PT100
calibration lower
limit digital
0
–4096
1270
○
P28.17
EC PT1000
detected OH
protection
threshold
0.0
–150.0°C
120.0°C
○
P28.18
EC PT1000
detected OH
pre-alarm
threshold
0.0
–150.0°C
100.0°C
○
P28.19
PT1000
detected
temperature
calibration upper
limit
50.0
–150.0°C
120.0°C
○
P28.20
EC PT1000
detected
temperature
calibration lower
limit
-20.0
–50.0°C
10.0°C
○
P28.21
EC PT1000
calibration upper
limit digital
0
–4096
3100
○
P28.22
EC PT1000
calibration lower
limit digital
0
–4096
1100
○
P28.23
Detecting for
PT100/PT1000
disconnection
from EC
0x00
–0x11
Ones place: PT100 disconnection detection
0: Disable
1: Enable
Tens place: PT1000 disconnection detection
0: Disable
1: Enable
0x00
◎
P28.24
Enabling digital
calibration in EC
PT100/PT1000
temperature
detection
0
–4
0: Disable
1: Enable PT100 lower limit digital calibration.
2: Enable PT100 upper limit digital calibration.
3: Enable PT1000 lower limit digital calibration.
4: Enable PT1000 upper limit digital calibration.
0
○
P28.25
Type of sensor
for AI/AO card to
detect motor
temperature
0
–3
0: No temperature sensor
1: PT100
2: PT1000
3: KTY84
0
◎