Goodrive350 IP55 High-ingress Protection Series VFD
Function parameter list
-244-
Function
code
Name
Description
Default
value
Modify
2: Open loop tension torque control
3: Close-loop tension torque control
P93.01
Actual winding/
unwinding mode
0
–1
0: Winding
1: Unwinding
0
●
P93.02
Initial roll
diameter
0.0
–5000.0mm
0.0mm
●
P93.03
Reset roll
diameter
0.0
–5000.0mm
0.0mm
●
P93.04
Roll diameter
change rate
0.00
–655.35 mm/s
0.00
mm/s
●
P93.05
Present roll
diameter
0.0
–5000.0mm
0.0mm
●
P93.06
Roll diameter for
linear speed
calculation
0.0
–5000.0mm
0.0mm
●
P93.07
Set linear speed 0.0
–6000.0 m/min
0.0 m/min
●
P93.08
Present linear
speed
0.0
–6000.0 m/min
0.0 m/min
●
P93.09
Main reference
frequency
0.00
–600.00Hz
0.00 Hz
●
P93.10
Actual
proportional gain
0.00
–30.00
0.00
●
P93.11
Actual integral
time
0.00
–30.00s
0.00s
●
P93.12
Proportional
output value
0
–65535
0
●
P93.13
Integral output
value
0
–65535
0
●
P93.14
PID upper limit -100.0
–100.0%
0.0%
●
P93.15
PID lower limit -100.0
–100.0%
0.0%
●
P93.16
PID output
frequency
-99.99
–99.99Hz
0.00Hz
●
P93.17
Main traction
running
frequency
-300.0
–300.0Hz
0.0Hz
●
P93.18
Set tension
0
–30000N
0N
●
P93.19
Tension taper
coefficient
0.0
–100.0%
0.0%
●
P93.20
Actual tension 0
–30000N
0N
●
P93.21
Basic torque
reference value
-300.0
–300.0%
0.0%
●
P93.22
Friction
compensation
-300.0
–300.0%
0.0%
●
Содержание GD350-004G/5R5P-45-AS