Goodrive350 IP55 High-ingress Protection Series VFD
Function parameter list
-238-
Function
code
Name
Description
Default
value
Modify
P90.18
Initial roll
diameter 2
P90.15
–P90.16 mm
100.0 mm
○
P90.19
Initial roll
diameter 3
P90.15
–P90.16 mm
100.0 mm
○
P90.20
Linear speed roll
diameter
calculation filter
time
0.000
–60.000s
2.000s
○
P90.21
Linear speed roll
diameter
calculation
restriction
0x00
–0x11
Ones place:
0:No
1: Restrict changes in reverse direction
Tens place:
0: No
1: Automatic restriction according to running
frequency and material thickness
0x00
○
P90.22
Material
thickness
0.001
–65.535mm
0.010 mm
○
P90.23
Number of coils
per layer
1
–10000
1
◎
P90.24
Revolution
counting function
selection
0
–2
0: Digital terminal input
1: PG card input
(Applicable to thickness calculation method)
2: Running frequency
(No input automatic revolution counting)
0
◎
P90.25
Number of
pulses per
revolution
1
–60
1
◎
P90.26
Roll diameter set
value
0.0
–100.0%
80.0%
○
P90.27
Roll diameter
reset setting
0x0000
–0x1111
Ones place: At stop
0: Remain current roll diameter
1: Restore to initial roll diameter
Tens place: Power off at running
0: Remain current roll diameter
1: Restore to initial roll diameter
Hundreds place: Reach the roll diameter set
value
0: Remain current roll diameter
1: Restore to initial roll diameter
Thousands place: Terminal reset limitation
0: Reset allowed at running
1: Reset only allowed at stop
0x1000
○
P90.28
Tension PID
0
–1
0
○
Содержание GD350-004G/5R5P-45-AS
Страница 1: ...Goodrive350 IP55 High ingress Protection Series VFD ...