Goodrive350 IP55 High-ingress Protection Series VFD
Basic Operation Instructions
-65-
Ready
P00.01=0 (controlled by
keypad)
Motor type
(P02.00)
P02.00=1
P02.00=0
Input motor nameplate
(P02.15
–
P02.19)
Input motor nameplate
(P02.01
–
P02.05)
Complete parameter
rotary autotuning
Partial parameter rotary
autotuning
Set autotuning mode
(P00.15)
Press "RUN" key to start
autotuning
Autotuning finished
During autotuning
Synchronous
motor
Asynchronous
motor
Complete parameter
static autotuning
Note:
1. Motor parameters must be set correctly according to motor nameplate;
2. If rotary autotuning is selected during motor autotuning, it is a must to disconnect the motor
from load to put the motor in static and no-load state, failed to do so may lead to inaccurate
autotuned results. At this time, the asynchronous motor can autotune P02.06
–P02.10, and
synchronous motor can autotune P02.20
–P02.23
3. If static autotuning is selected during motor autotuning, there is no need to disconnect the
motor from load, as only part of the motor parameters have been autotuned, the control
performance may be impacted, under such situation, the asynchronous motor can autotune
P02.06
–P02.10, while synchronous motor can autotune P02.20–P02.22, P02.23
(counter-emf constant of synchronous motor 1) can be obtained via calculation.
4. Motor autotuning can be carried out on current motor only, if users need to perform
autotuning on the other motor, switch over the motor through selecting the switch-over
channel of motor 1 and motor 2 by setting the ones of P08.31.