Goodrive350 IP55 High-ingress Protection Series VFD
Function parameter list
-183-
Function
code
Name
Description
Default
value
Modify
during
undervoltage
stall
P11.20
Integral
coefficient of
current
regulator
during
undervoltage
stall
0
–2000
150
○
P11.21
Proportional
coefficient of
voltage
regulator
during
overvoltage
stall
0
–1000
60
○
P11.22
Integral
coefficient of
voltage
regulator
during
overvoltage
stall
0
–1000
10
○
P11.23
Proportional
coefficient of
current
regulator
during
overvoltage
stall
0
–1000
60
○
P11.24
Integral
coefficient of
current
regulator
during
overvoltage
stall
0
–2000
250
○
P11.25
Enable VFD
overload
integral
0: Disable
1: Enable
0
◎
P11.26
Reserved
/
/
/
P11.27
VF vibration
control
method
0x00
–0x11
Ones place:
0: Method 1
1: Method 2
0x00
◎