Goodrive300-01A series VFD for air compressor
Function description
-77-
Function
code
Name
Description
Default
Modify
while the keypad TRIP indicator flashes. The
warning code only acts as a warning prompt,
and does not lead to failure shutdown.
P17.40
Status of
expansion card
0: No card
1: IO card
0
●
P17.41
Software
version of
expansion card
0.00
–655.35
0.00
●
P18 group Functions for air compressors
Function
code
Name
Description
Default
Modify
P18.00
Air compressor
control mode
0: Invalid
1: Air-compressor control mode
2: Water-lubricated air compressor control
mode
Note:
When
value, P19 group (Air compressor status
viewing) is valid.
0
◎
P18.01
Sleep function
selection
0: Invalid
1: Sleep mode 1
2: Sleep mode 2
Note:
When sleep function is valid and
unloading conditions are fulfilled, the VFD
decelerates to
frequency], and then, if discharge pressure is
and then coast to stop to enter sleep stage. If
the discharge pressure is less than loading
pressure during
, the VFD will
perform loaded running again, and pressure
PID will regulate accordingly.
1
◎
P18.02
Loading/unloading
mode
0: Automatic;
1: Manual
When setting to manual state, after air
compressor
starts,
loading/unloading
manually; when setting to automatic mode,
0
○