Goodrive300-01A series VFD for air compressor
Communication protocol
-173-
Function
description
Address
definition
Data meaning
R/W
characteristics
BIT3: =1 running time of part 4 cleared to
zero =0: invalid
BIT4: =1 running time of part 5 cleared to
zero =0: invalid
BIT5: =1 device running time cleared to
zero =0: invalid
BIT6: =1 solenoid valve loading =0:
solenoid valve unloading
2010H
The set maintenance time of part 1;
Range: 0
–65535
W
2011H
The set maintenance time of part 2;
Range: 0
–65535
W
2012H
The set maintenance time of part 3;
Range: 0
–65535
W
2013H
The set maintenance time of part 4;
Range: 0
–65535
W
2014H
The set maintenance time of part 5;
Range: 0
–65535
W
2015H
Running time of part 1, 0
–65535
W
2016H
Running time of part 2, 0
–65535
W
2017H
Running time of part 3, 0
–65535
W
2018H
Running time of part 4, 0
–65535
W
2019H
Running time of part 5, 0
–65535
W
201AH
Running time of the device: 0
–65535
W
201BH
Start/stop command of power-frequency
fan, 0
–3
W
VFD state word
1
2100H
0001H: In forward running
R
0002H: In reverse running
0003H: In stopping
0004H: In fault
0005H: VFD Poff state
0006H: VFD pre-exciting state
VFD state word
2
2101H
Bit0: =0: Not ready to run =1: Ready to run
Bi1
–2: =00: Motor 1 =01: Motor 2
=10: Motor 3 =11: Motor 4
Bit3: =0: Asynchronous motor
=1: Synchronous motor
R
Содержание GD300-01A