Goodrive300-01A series VFD for air compressor
External optional accessories
-148-
Master parameter
Initial value
Function
Upper limit of
running frequency
50.00Hz
It indicates the upper limit of the output frequency of
the VFD.
Lower limit of
running frequency
00.00Hz
It indicates the lower limit of the output frequency of
the VFD.
Loaded running
frequency lower limit
40.00Hz
It indicates the minimum working frequency that is
allowed to output when the pressure exceeds the
set value but does not reach the unloading pressure
during regulation.
Empty-load running
frequency
38.00Hz
It indicates the working frequency when the air
compressor is empty loaded.
ACC time
Model
depended
It indicates the time taken by the VFD to accelerate
from 0Hz to the maximum frequency.
DEC time
Model
depended
It indicates the time taken by the VFD to decelerate
from the maximum frequency to 0Hz.
2. You can edit parameters only after entering a correct administrator password.
03.17 16:02:35
Home
Please enter current password:
Return
Confirm
000
0
Figure B-36 Administrator password input interface
03.17 16:02:35
Home
Set value
Return
Confirm
Max Output Freq
xxx.x Hz
Max. 600.00 MPa
Min. 000.00 MPa
x
Figure B-37 Maximum output frequency setting interface