Goodrive300-01A series VFD for air compressor
Function description
-76-
Function
code
Name
Description
Default
Modify
Setting range: -100.0
–100.0%
P17.25
Motor power
factor
-1.00
–1.00
0.0
●
P17.26
Current
running time
0
–65535m
0m
●
P17.28
ASR controller
output
-300.0%
–300.0% (of the motor rated current)
0.0%
●
P17.29
Magnetic pole
angle of SM
0.0
–360.0
0.0
●
P17.30
Phase
compensation
quantity of SM
-180.0
–180.0
0.0
●
P17.31
High-frequency
superposition
current of SM
0.0%
–200.0%
0.0
●
P17.32
Flux linkage 0.0%
–200.0%
0.0
●
P17.33
Exciting
current
reference
-3000.0
–3000.0A
0.0
●
P17.34
Torque current
reference
-3000.0
–3000.0A
0.0
●
P17.35
AC incoming
current
0.0
–5000.0A
0.0
●
P17.36
Output torque -3000.0Nm
–3000.0Nm
0.0Nm
●
P17.37
Motor overload
count value
0
–100 (OL1 fault is reported when the count
value reaches 100)
0
●
P17.38
PID output
value
Display the output value of PID control of
discharge pressure signal; 100%
corresponds to max. output frequency
Setting range: -100.00
–100.00%
0.00%
●
P17.39
Warning code
The warning code is the same as P07.27
–
P07.31.
This warning code is generally used in
conjunction with P25 group Fault policy
functions to display a VFD pre-warning signal
0
●