Goodrive300-01A series VFD for air compressor
Function description
-88-
Function
code
Name
Description
Default
Modify
BIT15: Emergency stop signal
1: Emergency stop signal alarm, 0: Normal
P19.15
Device state
0: Standby
1: Run
2: Fault
3: Emergency stop
4: Undervoltage
5: Alarm
6: Sleep
7: In stopping
8: Restart delay
0
●
P19.16
Accumulated
running time
Display range: 0
–65535h
0
●
P19.17
Accumulated
load-carrying
running time
0
●
P19.18
Restart
count-down
Display the remaining time of restart delay.
After the system stops, it will enter restart
delay state and restart count-down to prevent
immediate restart. After restart delay time is
up, the system enters standby state. Under
standby state, start command can be
received.
Setting range: 0
–3600s
0s
●
P19.19
Output value
of
temperature
PID
Display the output value of temperature PID
regulation
of
machine
head,
100%
corresponds to max. output frequency
) of the fan.
Setting range: 0.00
–100.00%
0.00%
●
P19.20
Present
auxiliary
pressure
Display the auxiliary pressure value detected
at present.
0.00Mpa
●