Goodrive300-01A series VFD for air compressor
External optional accessories
-143-
03.17 16:02:35
Home
Current value
Return
Clear
Oil filter run time
xxxxx h
Figure B-27 Accumulative oil filter use time
B.2.4.8 Protection parameter interface
1. Enter the protection parameter interface through the main menu.
03.17 16:02:35
Home
Prealarm Pressure xxx.xx MPa
Return
Edit
Protection param
Alarm Pressure xxx.xx Mpa
Prealarm Temp xxxxxx
Alarm Temp xxxxxx
Low Temp Protect Thred xxxxxx
Auxiliary Press Protection Invalid
03.17 16:02:35
Home
Auxiliary Temp Alarm xxxxxx
Return
Edit
Protection param
Auxiliary Press Alarm xxx.xx MPa
Auxiliary Temp Proteciton Invalid
Present Auxiliary Temp xxxxxx
Auxiliary Temp Prealarm xxxxxx
Auxiliary Press Prealarm xxx.xx MPa
Figure B-28 Protection parameter interface
Protection
parameter
Initial
value
Function
Prealarm
temperature
105°C
When the actual exhaust temperature is higher than this
temperature, a pre-alarm is reported.
Alarm temperature
110°C
When the actual exhaust temperature is higher than this
temperature, an alarm is reported, and the device is stopped.