Goodrive300-01A series VFD for air compressor
Function description
-54-
Function
code
Name
Description
Default
Modify
rated current of the motor)
6: Output voltage (relative to 1.5 times the
rated voltage of the VFD)
7: Output power (relative to two times the
rated power of the motor)
8: Reserved
9: Output torque (relative to two times the
rated torque of the motor)
10
–13: Reserved
14: Value 1 set through Modbus
communication
15: Value 2 set through Modbus
communication
16
–21: Reserved
22: Torque current (relative to three times the
rated current of the motor)
23: Ramp reference frequency (with sign)
24: Temperature PID output
25
–30: Reserved
P06.15
RO6 output
selection
Same as P06.00
–P06.04
0
○
P06.17
AO1 output
lower limit
-100.0%
0.0%
○
P06.18
AO1 output
corresponding
to lower limit
0.00V
–10.00V
0.00V
○
P06.19
AO1 output
upper limit
–100.0%
100.0%
○
P06.20
AO1 output
corresponding
to upper limit
0.00V
–10.00V
10.00V
○
P06.21
AO1 output
filter time
0.000s
–10.000s
0.000s
○
P06.22
RO6
switch-on
delay
0.000
–50.000s
0.000s
○