Goodrive300-01A series VFD for air compressor
Function description
-80-
Function
code
Name
Description
Default
Modify
Setting range: 0
–3600s
P18.17
Pre-alarm
pressure
When current discharge pressure is higher
, the system indicates pressure
pre-alarm by setting BIT8 of
to 1.
When current discharge pressure is higher
, the system indicates pressure
alarm by setting BIT10 of
emergency-stop will be applied.
Setting range: 0.00
0.90Mpa
○
P18.18
Alarm pressure
1.00Mpa
○
P18.19
Pre-alarm
temperature
When machine head temperature is higher
than
the
system
indicates
temperature pre-alarm by setting BIT9 of
to 1.
When the machine head temperature is
higher than
, the system indicates
temperature alarm by setting BIT11 of
to 1, and emergency-stop will be
applied.
When machine head temperature is lower
than
the
system
indicates
low-temperature pre-alarm by setting BIT14
of
to 1, and air compressor cannot
start.
Setting range: -20
–150
105
℃
○
P18.20
Alarm
temperature
110
℃
○
P18.21
Low-temperature
protection
threshold
-10
℃
○
P18.22
Power calibration
coefficient
It is used to calibrate the displayed value of
[actual motor output power].
Setting range: 0%
–200%
100%
○
P18.23
Temperature PID
calculation cycle
(Ts)
Set the sampling cycle of temperature PID.
Setting range: 0.0
–10.0s
2.0s
○
P18.24
Gain coefficient
(kp)
It determines the regulation intensity of
temperature PID regulator, the larger the
value of kp, the stronger the regulation
intensity, however, if it is too large,
temperature oscillation may occur, users can
fine-tune based on the default value.
Setting range: 0.0
–100.0
18.0
○