Goodrive300-01A series VFD for air compressor
Function description
-48-
Function
code
Name
Description
Default
Modify
function
selection
4: Jog forward
5: Jog reversely
6: Coast to stop
7: Reset faults
8: Pause running
9: External fault input
10
–24: Reserved
25: Pause PID control
26
–39: Reserved
40: Clear electricity consumption
41: Keep electricity consumption
42: Air filter blockage signal
43: Oil filter blockage signal
44: Separator blockage signal
45: Precision splitter blockage signal
46: External fault 1 (motor overtemperature)
47: External fault 2
48: Fan running control signal
49: Solenoid valve control signal
50: Cooling fan control signal of main motor
51: PTC signal
52: Low water level detection (only for water
lubrication)
53: Medium water level detection (only for
water lubrication)
54: High water level detection (only for water
lubrication)
55: Extra water level detection (only for water
lubrication)
51
–63: Reserved
P05.04
Function of S4
0
◎
P05.05
Function of S5
0
◎
P05.06
Function of S6
0
◎
P05.07
Function of S7
0
◎
P05.08
Function of S8
0
◎
P05.10
Input terminal
polarity
The function code is used to set the polarity of
input terminals.
When a bit is 0, the input terminal is positive;
when a bit is 1, the input terminal is negative.
BIT7
BIT6
BIT5
S8
S7
S6
BIT4
BIT3
BIT2
BIT1
BIT0
S5
S4
S3
S2
S1
0x00
○