Goodrive300-01A series VFD for air compressor
Fault information and fault handling
-108-
P19.13
State type
Possible cause
Solution
protection threshold set by
P18.21.
circuit is abnormal.
• Actual temperature is too
low, and low -temperature
pre-alarm
is
reported
accordingly, and therefore
the air compressor cannot
start.
P19.14
State type
Possible cause
Solution
BIT0=1
Part 1 needs
maintenance
The running time of part 1
exceeds the time set by
P19.00.
Carry out maintenance after
stop
BIT1=1
Part 2 needs
maintenance
The running time of part 2
exceeds the time set by
P19.01.
Carry out maintenance after
stop
BIT2=1
Part 3 needs
maintenance
The running time of part 3
exceeds the time set by
P19.02.
Carry out maintenance after
stop
BIT3=1
Part 4 needs
maintenance
The running time of part 4
exceeds the time set by
P19.03.
Carry out maintenance after
stop
BIT4=1
Part 5 needs
maintenance
The running time of part 5
exceeds the time set by
P19.04.
Carry out maintenance after
stop
BIT5=1
Auxiliary pressure
signal fault
The actual voltage detected
by P2 is less than 1V.
• Pressure detection sensor
is abnormal.
• Pressure detection input P2
signal wire is disconnected.
BIT6=1
Auxiliary
temperature signal
fault
PT100
sensor
is
disconnected.
• Check whether the wiring of
PT100 is normal.
• Temperature
detection
sensor is abnormal.
• Temperature detection input
circuit is abnormal.