Goodrive300-01A series VFD for air compressor
Wiring instruction
-24-
Category
Sign
Name
Terminal function
PE to 0V
short connect the jumper J7 between 0V and PE
depending on the situation.
J10
PE/CGND
selection
terminal
CGND is short connected by default. When
interferences occur to communication, you can short
connect the jumper J10 to PE so as to help the
communication cable shielding layer connect to PE.
●
●
●
COM
+24V
PW
COM
+24V
•
•
S1
S2
•
J9
COM
+24V
PW
COM
+24V
•
•
S1
S2
•
●
●
●
+24V
J9
Figure 3-23 Internal power (NPN mode) Figure 3-24 External power (PNP mode)
When digital input S1 and S2 use in24V, set J9 according to Figure 3-23 and short +24V to
PW.
When digital input S1 and S2 use ex24V, set J9 according to Figure 3-24, and short COM to
PW.