Goodrive300-01A series VFD for air compressor
Function description
-84-
Function
code
Name
Description
Default
Modify
to ensure the running current of the master is
below the automatic frequency reduction
threshold.
P18.45
Maintenance
timeout time
0
–8000h
When it is set to
“0”, maintenance timeout
function will be invalid. When it is set to a
non-zero value, after parts maintenance
pre-alarm is reported, if the VFD continues
working until exceeding the value set by
P18.45, the system will report maintenance
timeout pre-alarm, and BIT11 of
be set t
o “1”.
0
○
P18.46
Input overvoltage
threshold
0
–2000V
484V
○
P18.47
Input
undervoltage
threshold
0
–2000V
250V
○
P19 group Air compressor status viewing
Function
code
Name
Description
Default
Modify
P19.00
The set time
of
maintenance
on part 1
maintenance on five kinds of parts. If the
accumulated running time of the part
exceeds the corresponding set value, the BIT
of
pre-alarms; if it is set to
“0”, the running time
pre-alarm will be invalid.
–P19.09 displays the running time of
corresponding parts.
Range: 0
–65535h
0
●
P19.01
The set time
of
maintenance
on part 2
0
●
P19.02
The set time
of
maintenance
on part 3
0
●
P19.03
The set time
of
maintenance
on part 4
0
●