Goodrive300-01A series VFD for air compressor
Function description
-47-
Function
code
Name
Description
Default
Modify
P04.09
V/F slip
compensation
gain of motor 1
0.0
–200.0%
100.0%
○
P04.10
Low-frequency
oscillation
control factor
of motor 1
0
–100
10
○
P04.11
High-frequency
oscillation
control factor
of motor 1
0
–100
10
○
P04.12
Oscillation
control
threshold of
motor 1
0.00Hz
(max. output frequency)
30.00Hz
○
P04.26
Energy-saving
run
0: Disable
1: Automatic energy-saving run
0
◎
P04.33
Weakening
coefficient in
constant power
zone
1.00
–1.30
1.00
○
P04.34
Reactive
closed-loop
proportional
coefficient
0
–3000
100
○
P04.35
Reactive
closed-loop
integral
coefficient
0
–3000
30
○
P05 group Input terminals
Function
code
Name
Description
Default
Modify
P05.00
Reserved
Reserved
0
◎
P05.01
Function of S1 0: No function
1: Run forward
2: Run reversely
3: Three-wire running control
0
◎
P05.02
Function of S2
0
◎
P05.03
S3/PTC
terminal
0
◎
Содержание GD300-01A
Страница 1: ......
Страница 187: ...6 6 0 0 1 0 0 7 6 1...