Goodrive300-01A series VFD for air compressor
Function description
-74-
P17 group Status viewing
Function
code
Name
Description
Default
Modify
P17.00
Set frequency 0.00Hz
0.00Hz
●
P17.01
Output
frequency
0.00Hz
0.00Hz
●
P17.02
Ramp
reference
frequency
0.00Hz
0.00Hz
●
P17.03
Output voltage 0
–1200V
0V
●
P17.04
Output current 0.0
–3000.0A
0.0A
●
P17.05
Motor speed 0
–65535RPM
0 RPM
●
P17.06
Torque current -3000.0
–3000.0A
0.0A
●
P17.07
Excitation
current
-3000.0
–3000.0A
0.0A
●
P17.08
Motor power
-300.0%
–300.0% (relative to rated motor
power)
0.0%
●
P17.09
Output torque -250.0
–250.0%
0.0%
●
P17.10
Estimated
motor
frequency
0.00
0.00Hz
●
P17.11
DC bus voltage 0.0
–2000.0V
0V
●
P17.12
Digital input
terminal status
0000
–00FF
0
●
P17.13
Digital output
terminal status
0000
–000F
0
●
P17.16
Master fault
code
0
–43 (see
0
●
P17.17
Reserved
0
–1000
0
●
P17.18
Auto fault reset
count of
present fault
0
–20
0
●
P17.19
P1- input
voltage
Display analog input voltage value of P1-
channel, 2.00V
–10.00V corresponds to 4–
20mA;
correspond
to
pressure 0.0
. If P1- input voltage is
larger than 9.8V or less than 1V, it indicates
pressure signal fault occurs.
Range: 0.00
–10.00V
0.00V
●
Содержание GD300-01A