TwinLock B670/C690 CashProtect DS
Operation
Manual V.1.01B
58
4.14.7
Parallel Code
Optional selection of
Parallel code
for lock systems with 2 locks (at
least).
The first user can open lock 1, 2 or 3, the second user opens the other
lock or one of the two locks still closed and the third, if required, closes
the last lock. It is not possible for one user to open all locks.
Can be combined with „
Forced sequence
“. With 2 lock systems, a user
can open a safe alone during „
Part lock time
“.
Upon selecting this option via optional PC software,
option „
Dual code
“
will become inactive automatically.
Activation similar to that of „Dual
code“ (see above)
.
4.14.8
Forced Sequence
Optional selection of
Forced sequence
for lock systems with 2 locks
(at least).
If you select option ‘Forced sequence’, users have to open lock 1 before
they can open lock 2. The system defines that order. The user cannot
change it. This function simplifies the operation. The system is ‘par
tly
locked’ (which corresponds to state ‘locked’ with option FS deactivated)
when lock 1 has been opened. With all locks open, the system is
‘unlocked’, not protected.
Closing order: Lock 2 closes at first and lock 1 closes thereafter. Only after
lock 1 ha
s closed, the system is ‘locked’, protected.
Default setting: ‘Forced sequence’ off. Activation similar to that of „Dual
code“ (see above).
4.14.9
Time delay
Option of setting different types of
Time delay
for locks or for persons
who have been assigned week table periods (week programs). You can
set 3 2-digit values in minutes
00<00<00
.
The first (left) value defines the opening delay, the second the release time
and the third the alarm delay or the opening delay upon alarm.
Default setting: Off. Activation similar to that of „Dual code“ (see above).
4.14.10
Time locked / Week Programs
Option of programming 5
Week programs
. For every program you can
set two times for every week day, the time of the beginning and the ending
of a daily opening period,
Mo:08:00-17:00
, for example.
These week programs can be assigned to persons when these persons are
registered / created for the first time. Default setting: Off. Activation similar
to that of „Dual code“ (see above).