4.5
The System Status and Mode
4.5.1
The System Status
System settings can be modified and changed with the system unlocked.
Only menus
Open
,
Close
and
Status / Info
are on display on the operating
unit with the system locked.
In order to unlock the system,
- open lock 1 (with option
‘
Forced sequence
’
off [FS off])
or
- open all locks (with option
‘
Forced sequence
’
on [FS on]).
With option
‘
Forced sequence
’
activated, users cannot select which lock of a
system with 2 locks they open or close. Also see the glossary.
System States:
Unlocked
:
Lock 1 (
‘Forced sequence’
off [FS off]) / all locks (with FS on) open,
all menus on display, system settings can be modified.
Partly locked
: at least one lock open and one lock closed (with FS only), restricted
menu display, system settings cannot be modified.
Locked
:
Lock 1 (with FS off) / all locks (with FS on) closed, restricted menu
display, opening and emergency functions available, system
settings cannot be modified.
The state of the system depends on whether option ‘Forced sequence’ (FS) has
been set via PC software during configuration:
System status with
‘
Forced sequence
’
OFF
Unlocked / not secure, when all locks are open.
With this setting there is no state
‘
Partly blocked
’
.
Locked, when lock 1 is locked. Menu display restricted.
System status with
‘
Forced sequence
’
ON
Unlocked / not protected, when lock 1 is open. Display of all menus.
Partly blocked when at least one lock is closed and another lock is open.
Locked, when all locks are locked.
Status contact of TwinAlarm / TwinXT (optional)
Only with systems with TwinXT / TwinAlarm:
Contact in state
‘
open
’
/
‘
closed
’
, when lock 1 is open / closed.
System signal of status contact of TwinAlarm / TwinXT (optional)
Only with systems with TwinXT / TwinAlarm:
System signal indicates
‘
open
’
/
‘
closed
’
, when lock 1 is open / closed.
4.5.2
Mode / CIT Function
Define via t
his setting (submenu “
Settings/Manager/CIT Function
”) whether users
have to use flexible OTC (single use code) or whether they can or cannot use it.
Mode („CIT function / mode“) of the system („1“ and „2“ with B650 / B670 only):
0 = Bank:
Users open via PIN code.
1 = Mix:
Mixed mode; lock systems may have mode 0 or 2.
2 = CIT:
Users open locks with flexible OTC (1x- / Single-use code).