TwinLock B670/C690 CashProtect DS
Operation
Manual V.1.01B
40
4.10
PIN Codes
Caution
The system is not protected with ex works versions of
system manager
–
and master code.
Danger of unauthorised opening.
Due to security reasons, change the ex works versions of codes
as soon as possible.
Codes consisting of numbers that correspond to personal
data like birthday dates might be guessed at.
Danger of unauthorised opening.
Avoid using numbers that might be guessed at by people with
access to your personal data.
The master code can be deleted.
Danger of loss of functions.
Do not delete the master code. If required, the manager can
authorise the master anew.
4.10.1
Types and Numbers of PIN Codes in Every Lock
- 1 system manager code (without authorisation to open the lock)
- 1 master code (with optional authorisation for lock opening)
- 1 CIT master code (with optional authorisation for lock opening)
- 1-99 user PIN codes with optional authorisation to open the lock, also see section
‘User Authorisation’ in this chapter).
With the
manager code
of lock no.1, the whole system can be configured. This code
also is called
system manager code
, system code in short, and its bearer is called
system manager. The holder of this code also administers the system IDs A and B,
as it may be.
With the
master code
of a lock, the PIN codes of the users can be registered and
deregistered. The code bearer is called the lock master, who can optionally be
authorised to open the lock by the system manager. Manager codes cannot be
deregistered.
With every user
PIN code
registered at a lock by the lock master, users who have
been authorised to do so, can open the lock.
PIN codes for users are not programmed ex works. Via the user matrix of the PC
software, the individual authorisation of users is defined. The PIN codes can be
programmed / registered and deregistered by the lock master. Depending on their
authorisation, users may be able to change their PIN code autonomously.
The number of digits of a PIN code (for users, lock master, manager and system
manager) depends upon the VdS class of the system. VdS Schadenverhütung
(= VdS damage prevention) is an accredited and notified testing and certifying
institution for elements providing physical and electronic protection against
intrusion.
The
VdS class
of TwinLock CashProtect can be displayed with menu
Status /
Info
at the operating unit.
TwinLock systems of VdS class 2 contain locks type VdS2 only, systems of VdS class
3 contain locks type VdS3. With VdS class 2systems, PIN codes consist of six digits.
Ex Works Master- / System Manager Codes of TwinLock CashProtect
Master
System / Manager
VdS class 2
123456 (user 00)
111111 (user 225)