TwinLock B670/C690 CashProtect DS
Operation
Manual V.1.01B
83
4.18.2
Messages During Configuration Import
During the import of a configuration the error messages listed below may be on
display in the second display line. The display features two lines.
Config. error
in the first line indicates that an invalid value has been allotted to
a parameter.
Lock system
in the first line indicates that the configuration does not fit to the
(hardware of) the system.
Modify invalid parameters via optional software CashProtectPro or TwinNet and
import the configuration again.
Text in the second line of the display:
Alarm delay
✓
The alarm delay triggered simultaneously with silent alarm has been set
to last longer than the permitted 0-99 minutes.
✓
Enter a value within the permitted range of values.
PIN code
✓
Not enough PIN codes in the System. If the configuration were
imported, no one could open the lock.
✓
Increase the number of authorised users in the system.
Special days
✓
An invalid date has been entered for a ‘Special day’.
✓
Amend the data for time
program ‘Special days’.
Block period
✓
At least one invalid date has been
entered for ‘Block period’.
✓
Amend the data for time
program ‘Block period’.
Silent alarm
✓
The value for ‘Alarm digit’ is not within the range of ‘01
-
09’.
✓
Enter a value within the permitted range of values.
Door open
✓
The value for ‘Open door monitoring’ is n
ot within the permitted range
of ‘00
-
99 minutes’.
✓
Enter a value within the permitted range of values.
Weekly program
(Week table)
✓
An invalid time has been entered for ‘Weekly program’.
✓
Enter a value within the permitted range of values.
Time delay
✓
The valu
e for ‘Unlocking delay’ / ‘Time delay’ of the lock is not within
the permitted range of ‘00
-
99 minutes’.
✓
Enter a value within the permitted range of values.