background image

TOEPC72060013

M3 x 6 

M5

ø6 mm

M5

Phillips #2

TOEP C720600 13C Remote Keypad Mounting Kit Instruction Manual

9

This installation kit is compatible with keypad models JVOP-KPLxxxxxxx.

Please refer to the Installation Manual packaged with the drive or keypad when you install this option. 

6 ea.

ø6 (0.24) 

mm (in)

75 (3.0)

minimum

clearance

Side View

100 (3.9)

131 (5.2)

165 (6.5)

minimum

clearance

117 ±1

(4.61 ±0.04) 

180 (7.1)

minimum

clearance

127 ±1

(5 ±0.04) 

72 (2.8)

72 (2.8)

5

Cut the Opening

1

Procedure for Installation of Remote Keypad Mounting Kit for UL Type 1, Type 12, Type 3R, and IP55 Enclosures

2

Compatible Products

3

Collect the Required Tools and Equipment

4

Make Sure the Kit Will Fit in the Desired Location

6

Snap-fit the Keypad (Not Included) into the Keypad Kit Subassembly

Use the measurements above or the template in 

A

 to cut the opening and drill or punch 6 each ø6 holes on 

the customer-supplied enclosure.  

You can also use the provided M3 x 6 flat head screws and tighten to 0.49 to 0.73 N•m (4.3 to 6.4 in•lb) for additional security. 

Use the provided M5 flange nuts and tighten the screws in the order shown below with initial torque. 

Gradually increase the torque to 2 to 2.5 N•m (17.1 to 22.1 in•lb) to evenly compress the gasket.

Select the customer-supplied keypad cable length best suited for the enclosure size. 

Plug one end of the cable into the female connector on the back side of the keypad. Plug the other end of the 

cable into the female connector on the front of the drive. 

The location of the connector is different for different drive models.

Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to comply will 

result in death or serious injury. Before servicing, disconnect all power to the equipment. The internal capacitor remains 

charged even after the power supply is turned off. The charge indicator LED will extinguish when the DC bus voltage is 

below 50 Vdc. To prevent electric shock, wait for at least the time specified on the warning label, once all indicators are 

OFF, measure for unsafe voltages to confirm the drive is safe prior to servicing. Failure to comply will result in death or 

serious injury.

DANGER

Measure the printed dimensions before you drill the screw holes. Moisture can cause the template scale to 

change.

NOTICE

7

Attach the Keypad Kit Subassembly to the Enclosure

8

Select the Keypad Cable

Отзывы: