TwinLock B670/C690 CashProtect DS
System Description
Manual V.1.01B
25
3.4.3
Optional Functions
The version of the firmware can be displayed via menu
Status / Info
. See page
52. Some of these functions can be programmed with the optional software
CashProtectPro. For functions, which depend on network connection, the optional
web-based software TwinNet is required.
Integration RFID
Available with hardware with RFID module only. Within a network (via TwinNet, for
example) as well as locally (via section
„
Code s
ettings“, field „Code
card“ in
CashProtectPro), you can configure the system in such a way that all users are
required to use contactless RFID cards / tags for user identification.
Users open with one time code (OTC, single-use code)
Within a network (via TwinNet, for example) as well as locally (via user matrix in PC
software), you can configure the system in such a way that selected users have to
enter 6-digit single-use-code in order to open the lock.
With this option selected for users, these users have to enter the following items in
order to open in the following way (and in the order given below):
User- / personnel number -> PIN code -> OTC (single-use code)
Silent alarm can be switched off
Within a network (via configuring the corresponding TwinNet system, for example)
as well as locally via PC software (via section
“Settings”,
icon
“Alarm”, field
“Silent
alarm”
in CashProtectPro), you can configure whether users should be able to trigger
silent alarm / duress alarm or not. With silent alarm deactivated, nobody can open
with the alarm code.
Data export and - import for selected users
With other parameters set accordingly, every user with valid PIN code can export
configuration data.
Every user with box
„Service“
marked (via TwinNet person / user matrix PC software)
can import configuration data.
Switching off / on unit TwinIP via operating unit
System managers can do this with the help of hidden menu, sub menu
„
Network
“
after having pressed the ENTER key and keep it depressed while the date is on
display.
Writing / reading network parameters via operating unit
With a system with network connection, you can set
the parameters „IP address“,
„
N
etmask“
a
nd „
G
ateway“
via menu
„
Net
work“
at the operating unit:
With the date on display, press and hold key ENTER -
> menu „Network“
-> Network
YES / NO -> YES -> Configuration YES / NO -> YES -> Write parameters named
above and confirm with key OK.
If „DHCP on“ is on display, the parameters will be set
automatically.
You can read the parameters „IP address“, „Netmask“, “MAC address”
and
„Gateway“ via menu „Network“
at the operating unit:
Press and hold key ENTER -
> menu „Network“
-> Network YES / NO -> YES ->
Configuration YES / NO -> NO -> Read parameters named above.
Users can be blocked after the validity of their code has expired
Within a network (via configuring the corresponding TwinNet system, for example)
as well as locally via PC software (via
tab “Settings”, tab sector below “Code vali
dity
expiration”, field
“User blocked after code aging
/ Period to blocking [months]
”
in
CashProtectPro, for example), you can configure whether and after how many
months users are to be blocked and deleted after the validity of their code has
expired.