TwinLock B670/C690 CashProtect DS
Operation
Manual V.1.01B
79
4.17.4
Registering a New Lock
The system manager can register a new lock in the system or replace
an existing lock via menu
Regist. new lock
.
Only new locks that have never been addressed before can be registered
via menu
Service | Regist. new lock
–
either in case a lock is
replaced (
Change lock
) or in case the system is extended by one lock
(
New lock
).
In order to register locks that have been addressed before, proceed in
the same way as when changing a terminal / operating unit. See
paragraph „Reset“ in this chapter.
Take
a new lock that has not been addressed before
1.
Unlock the system by opening lock 1 or by opening all locks
2. Select
Service
with key
>
and
Enter
.
Service | 1x bolt work
is on display.
3.
With
>
select
Regist. new lock
and press
Enter
.
Service | Regist. new lock
. is on display.
4.
Confirm with
Enter
.
Regist. new lock | New lock
is on display.
Additionally, perform the steps of “Additional New lock” in case one more lock
is
to be added to the system or perform the steps of “Changing a Lock“, if
locks are to be changed.
4.17.4.1
Additional Lock
is the sequel of „Registering a Lock“ in case you register an additional new lock.
Also see
„Changing Locks“ below.
5.
Confirm
New lock
with
Enter
.
Code entry
and
System manager
,
0123456789
, as the case may be,
and
Code:
. are on display.
6.
Enter the system manager code.
Please wait | New lock
,
Lock
2/3
and
! Insert bus cable !
.
are on display. The displayed lock number is the one that is allotted to the new
lock in the system (number of existing locks + 1).
7.
Confirm cable connection with Enter.
Serial number | Please wait
is on display.
The serial number of the operating unit is stored within the lock.
Serial number | Saved
is on display.
Error com | Setup error
would be on display if
the „new“ lock
had
been addressed before.
Saved
,
Lock X
,
Registered
and
CashProtect | 11.10.21
are on display.
You have successfully registered the additional lock.