background image

KeypadLinc

TM

Wall-Mounted Controller 

with Integrated Dimmer

For models:
#12073W & #12074W with Amber LEDs

#12073WB & #12074WB with Blue LEDs

#12073WW & #12074WW with White LEDs

Now Includes

BoosterLinc Signal

Boosting

(6-Button Models only)

1207x-Jun2004web.qxd  6/16/2004  3:28 PM  Page 1

Содержание KeypadLinc 12063W

Страница 1: ...Wall Mounted Controller with Integrated Dimmer For models 12073W 12074W with Amber LEDs 12073WB 12074WB with Blue LEDs 12073WW 12074WW with White LEDs Now Includes BoosterLinc Signal Boosting 6 Button...

Страница 2: ...steps involving the programming of the dimmer s primary address will be slightly different between the two versions KeypadLinc Features Includes Smarthome s BoosterLinc technology 6 Button models only...

Страница 3: ...Enter Setup mode hold any two keys for 5 seconds Programming 2 Press the button to be set 3 Confirm button s light is Blinking 4 Send the address and command to set the mode Bright Non dimmable modul...

Страница 4: ...eypadLinc may feel warm during operation The amount of heat generated is within approved limits and poses no hazards To minimize heat build up ensure that the area surrounding the rear of the KeypadLi...

Страница 5: ...entify the Hot Neutral Ground and Traveler wires 6 Orient KeypadLinc so the LED is at the top and make the connections accord ing to the KeypadLinc Wiring Diagram below 7 After all connections have be...

Страница 6: ...home s plug in BoosterLinc signal booster This feature allows it to boost PLC X10 signals on the AC line and improve the overall reliability of the automa tion system in the home The signal boosting c...

Страница 7: ...key Setting the Integrated Dimmer s Fade On Off Rate Optional The Fade On Off Rate is the speed that KeypadLinc brings the brightness of the connected light s up or down when activated manually or it...

Страница 8: ...justing the integrated dimmer s default on level 1 Transmit the clear sequence 2 Send the house unit code for the lamp module and adjust the dim level or send preset dim level 3 Send the following com...

Страница 9: ...inc Timer ApplianceLincTM 2 Way Plus Modules ToggleLincTM 2 Way and Plus Dimmers and Switch The scenes for all these modules can be setup simultaneously using the same pro gramming sequence Signals se...

Страница 10: ...ntegrated dimmer and adjust the dim level corresponding to the fade on off rate time you want using the table on page 8 brighter faster 3 Send the following command sequence 4 Transmit the scene addre...

Страница 11: ...example if you turned on a receiver only wall switch the indicator light on the KeypadLinc would not come on because most wall switches can t transmit If you need the modules to transmit when manuall...

Страница 12: ...Wall Switch Module When the button is pressed and held KeypadLinc sends BRIGHT and DIM signals on alternate presses DIM Button is for an Appliance Module that can confirm its ON OFF status KeypadLinc...

Страница 13: ...2000STW 2000STW3 ApplianceLincTM 2 Way 2002STW 2001STW I O LincTM Relay Controller1 1624 X10 2 Way Lamp Module LM14A 2000TW X10 2 Way Appliance Module AM14A 2001TW ACT 2 Way Switches RS 114 115 2270A...

Страница 14: ...Special Case BRIGHT DIM of Last Button Pressed KeypadLinc can send BRIGHT or DIM signals for the last unit code sent from anoth er button on the KeypadLinc regardless of the House Code 1 Enter the Set...

Страница 15: ...ton is left in a Group KeypadLinc will automatically dissolve the group so that the remaining button does not need to be removed from the group Special Notes About Groups Only Non Toggle buttons can j...

Страница 16: ...that more than one BoosterLinc equipped product will be required on a single line serviced by the same circuit breaker Having too many BoosterLinc enabled products installed and the BoosterLinc featur...

Страница 17: ...on t light up when PLC signals are received by the KeypadLinc The lights on the key pad do not match the status of the load KeypadLinc is locked up and not responding Keypad does not control the load...

Страница 18: ...mize your KeypadLinc please be gentle in remov ing the keys The buttons on the KeypadLinc 8 require extra special care in remov ing the keycaps Using a small flat edged screwdriver ONLY pry up on the...

Страница 19: ...siness will be to install a coupler repeater also known as amplifier A coupler repeater will see the incoming signal re generate it and blast it out over both lines of the 120 volts We recommend that...

Страница 20: ...n the last 20 years an explosion of electrical devices has invaded our homes Computers video gear and fancy high end electronics are more present than in years past The more complicated the electrical...

Страница 21: ...e effects of signal absorption mentioned earlier Plug in the signal meter and measure the signal s strength then unplug any devices that are plugged into that and nearby outlets If 10 or greater chang...

Страница 22: ...a scene signal to other KeypadLinc SwitchLinc and LampLinc the lighting mood instantly changes Maxi Controller A PLC transmitter that has separate buttons for the unit codes and the commands In some o...

Страница 23: ...Hz Max of KeypadLinc Controllers per multiple gang box 4 Max of KeypadLinc Controllers per circuit 10 with more than 6 a coupler repeater is recommended Mounts in single or multiple ganged J box Inves...

Страница 24: ...n authorization number properly package the product with the RA clearly printed on the outside of the package and send the product along with all other required materials to Smarthome ATTN Receiving D...