background image

User / Installation Guide

Stand Alone LCD Keypad / Repeater

Fighter KSDA

Version:

 1.0

Revision:

 2

Содержание fighter KSDA

Страница 1: ...User Installation Guide Stand Alone LCD Keypad Repeater Fighter KSDA Version 1 0 Revision 2 ...

Страница 2: ...When this crossed out wheeled bin symbol is attached to a product it means the product is covered by the European Directive 2002 96 EC 2 All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities 3 The correct disposal of your old appliance will help prevent potent...

Страница 3: ...Ds 6 6 Users Master Normal Installer 7 7 Access Levels 7 8 System Information and status 8 8 1 Installed modules Module Identification 8 9 Access Level 2 10 9 1 Evacuation Start 10 9 2 Bypass Zones 10 9 3 Bypass Relays 10 9 4 Bypass Information Screens 10 9 5 User s Code 11 9 6 Zone Descriptions 11 9 7 Periodic Test 11 9 8 Time Date Adj 11 9 9 Walk Test 11 9 10 Intellizone Cancel 12 TABLE OF CONTE...

Страница 4: ...rks as an indicator that can be lit or not e g ACC Button A Keypad button that can be pressed e g 5 Indicator A visual indicator that may be lit or not e g ALARM TEXT ON LCD DISPLAY Text that appears on the LCD display by the system TEXT ENTERED BY THE USER Text that appears on the LCD display as a result of user input The following terminology is used PSU Power supply unit A L Access Level ALM Ac...

Страница 5: ...cess level 2 and 3 programming changes character entry mode from numeric to T9 text entry mode as used on mobile and telephone devices FAULT Button Displays the system s FAULTS in two different screens The first press shows a list of zones in fault by pressing the button again the zones overview screen is shown Further presses of the FAULT button alternates between these two screens Alternative fu...

Страница 6: ...ke great care not to mix the data wires with the power wires as permanent damage may be caused B A MAIN BOARD Stand Alone LCD Keypad Repeater B GND Vbus A Next Module Figure 2 BUS connection 5 Setting keypad modules IDs 1 2 3 4 SW1 ON Figure 3 Set of dip switches All modules except the power supply units PSUs have a set of dip switches Figure 3 that controls their address on the bus system It is v...

Страница 7: ...s level 3 A L 3 may perform operations that belong to the Access level 2 A L 2 group 7 Access Levels The fire panel during it s operation is said to be in a specific access level from 1 to 3 Each access level defines what operations are allowed and what are protected Each Access Level may be activated or entered by entering the requested code or PIN for the corresponding access level Factory defau...

Страница 8: ...splay to find out which unit is currently in elevated access mode To ensure that the system will never be locked untenanted in elevated access level it detects user inactivity and drops to access level 1 automatically after a period of 30 seconds 8 System Information and status In Access level 1 A L 1 the user may request through the level s menu a number of information screens The A L 1 menu is s...

Страница 9: ...y second For Keypads the LCD backlight toggles on and off every second This mechanism helps the installer or maintainer to identify a module without margin for error To select a module In the Installed modules screen press ENTER A small i appears on the top left of the screen and a cursor is activated Move the cursor with the arrow keys over an installed module and press EN TER The module characte...

Страница 10: ...2 Bypass Zones To activate a bypass on a zone Press 2 to select menu item 2 Bypass Zones The list with all available zones is displayed Use Up Down keys to place the flashing cursor on the required zone Use the Right Arrow to activate a bypass and Left Arrow to cancel a by pass Once finished press CLR exit to access level 2 menu 9 3 Bypass Relays To activate a bypass on a relay Press 3 to select m...

Страница 11: ...press CLR exit to access level 2 menu 9 6 Zone Descriptions To zone descriptions Press 5 to select menu item 5 Zone Descriptions The zone description list is displayed Use Up Down keys to place the flashing cursor on the required zone Use ENTER to edit zone description by using the alphanumeric buttons Once finished press CLR exit to access level 2 menu 9 7 Periodic Test To activate a periodic tes...

Страница 12: ...re all the detectors of the installation one by one 9 10 Intellizone Cancel To cancel intellizone procedure if activated Press 9 to select menu item 9 Cancel Intellizone The Cancel Intellizone screen is displayed Press 1 to cancel intellizone procedure For A L 3 refer to Installation and Operation Manual ...

Страница 13: ..._______________ Zone 20 _____________________________ Zone 21 _____________________________ Zone 22 _____________________________ Zone 23 _____________________________ Zone 24 _____________________________ Zone 25 _____________________________ Zone 26 _____________________________ Zone 27 _____________________________ Zone 28 _____________________________ Zone 29 _____________________________ Zone...

Страница 14: ... 56 _____________________________ Zone 57 _____________________________ Zone 58 _____________________________ Zone 59 _____________________________ Zone 60 _____________________________ Zone 61 _____________________________ Zone 62 _____________________________ Zone 63 _____________________________ Zone 64 _____________________________ Zone 65 _____________________________ Zone 66 ________________...

Страница 15: ......

Страница 16: ...Document Part Number FIGHTER SDAUG version 1 0 revision 2 9 2021 1293 CPR 0651 ...

Отзывы: