34
Installation
Installation and Programming Manual
3-9-2
Connecting open-
collector outputs
All the system outputs, except for the relay output on the control panel
motherboard, are open-collector outputs.
•
OC1 and OC2 are open-collector outputs that sink maximum currents in
accordance with the
Table 3: Control panel - Main Features
.
•
All the terminals configurable as outputs are open-collector outputs that sink a
maximum current of 150 mA.
The wiring diagram below illustrates a series of typical connections which activate
the load of a Normally Open output when it closes to GND (
).
3-10
Attachment boards
3-10-1
AUXREL32
The AUXREL32 power distribution board (accessory item) can be used with
SmartLiving 1050L and 10100L models. It provides two relays and allows the
system to take full advantage of the current supplied by the control-panel power-
supply. It comprises 3 pairs of terminals protected by resettable fuses (GND/
AUX1 – GND/AUX2 – GND/AUX3), each able to provide 12V@1A.
Each relay, has a voltage-free contact identified by terminals C1-NO1-NC1 and
C2-NO2-NC2. The relays are activated by the control panel outputs OC1 and
OC2.
Control
panel
Self-powered
sounderflasher
Indoor
sounderflasher
SmartLiving
1050 control
panel
Generic load
12V
External
power supply
13.8V
Generic
device
Table 28:
AUXREL32 - description of parts
A
Terminal board
B
12V connector
C
OC1/OC2 connector
D
Relay LED 1
E
Relay LED 2
F
12V present LED
G
Screw locations
H
OC1/OC2 connection wire
I
12V power wire
A
C
E
F
D
G
A
G
G
B