Installation and Programming Manual
Options and programming methods
51
Monostable time
This parameter applies to “Monostable” outputs only. This interval can be
expressed in seconds or minutes (see “info” box).
When a “Monostable” output receives an activation signal, it will remain active
(On) for the programmed time, regardless of the status of the trigger-event. In
some cases, “Monostable” outputs can be forced to standby before the
programmed monostable time runs out.
Use keys
and and the number keys to set the times.
Via PC
Programming zones via the SmartLeague application is accomplished by the
selection and programming of the terminal configured as output, described in
paragraph
6-5 Terminals
.
6-8
Telephone
This programming section deals with all the telephone parameters.
The built-in ATS device (alarm transmitting system) provides the following
features (in compliance with EN50131 relating to the notification of information).
•
Type B notification apparatus (refer to EN50131-1:2008-02, paragraph 8.6
Notification, Table 10, page 46, Grade 2).
•
The ATS2 notification apparatus specified in the table, is characterized by:
•• Transmission time - classification D2 (60 seconds)
•• Transmission time - max. values M2 (120 seconds)
•• Classification time - classification T2 (25 hours)
•• Substitution security - S0 (no detection of device substitution)
•• Information security - I0 (no detection of message substitution)
Via Keypad
Type-in Code
(Installer PIN)
, PROGRAMMING Telephone
.
Select number
Use keys
and
to access the Phonebook which provides 10 number
positions with the following programming fields.
•
Number
: edit field for the contact number (maximum 20 digits). Accepts also
“,” (= 2 second pause), “*” and “#”.
•
Description
: edit field for the name of the contact person. Follow the
instructions in paragraph
6-6 Zones
.
•
Type
:
••
None
- the selected number can receive SMS text messages only
••
Voice
- the selected number can receive voice calls and SMS text
messages
If the number refers to the Alarm Receiving Centre, assigns the
ARC
protocol
(reporting format):
••
Ademco 10bps
••
Ademco 14bps
••
Franklin 20bps
••
Radionics 40bps
••
Scantronic 10bps
••
CONTACT-ID
••
SIA
- Level 1 SIA is applied This reporting format (protocol) is capable of
sending descriptions of the objects in ASCII characters. if you do not wish
to send the descriptions in ASCII characters, select “No SIA strings” (refer
to paragraph
6-4 Panel options
). You can set a 4, 5 or 6 digit customer
code for this protocol.
••
Ademco Express
Use
and
to select the Type of number, then press
.
•
Account code
: a 4-character alphanumeric code which identifies the caller in
reports to the Alarm Receiving Centre. Some protocols (reporting formats)
accept digits only, whilst others accept also “A”, “B”, “C”, “D”, “E” and “F”,
available using keys
.
If this value is
expressed in minutes,
there is an error
margin of 1 minute (for
example, if you set 5 minutes,
the period can vary between 4
and 5 minutes).
PROGRAMMING
Zones
Outputs
Telephone
Telephone
Select number
Number of rings
Max.num.attempts
Select number
NUMBER 001
NUMBER 002
NUMBER 003
NUMBER 001
Number
Description
Type