70
Options and programming methods
Installation and Programming Manual
4. Restore the short-circuit condition.
Within 70 seconds the control panel will reset to default settings, re-enroll all the
peripherals currently on the I-BUS and, if a keypad is connected, will ask you to
select the Language.
Reset to factory default will not clear the events log.
Via Keypad
1. Access the “Default settings” section:
Type in Code
(Installer)
, PROGRAMMING Default settings
.
2. Use keys
or
to select the function then press
:
Factory data
If you select this option, the control panel will reset entirely to default settings.
ATTENTION!
This operations deletes all the previously programmed parameters.
Learn zone bal.
If you select this option, the control panel will learn (save to memory)
automatically all the balancing settings of all the zones (
Patent Pending
).
The zone-balancing options are:
•
Normally Open
•
Normally Closed
•
Balancing (Single balancing)
•
Double balancing
•
Rollerblind with EOL
The balancing settings which are not acquired accurately are:
•
Rollerblind without EOL (which is classified as a normally-closed generic zone)
•
Double zone without EOL (which is classified as a normally-closed generic
zone)
•
Double zone with EOL (which is classified as a generic zone with Double
balancing)
In order to allow accurate acquisition of the balancing settings of all the zones,
you must:
•• Wire and select the balancing settings of all the zones.
•• Ensure that all the zones are in standby status
•• Select the “Learn zone bal.” option.
•• Verify that the operation has been carried properly and that all the settings
are accurate (if any zones are not in standby status during this process
their settings will not be acquired accurately).
•• Set manually any inaccurate settings.
Auto enrol Periph
If you select this option, the control panel will enroll automatically all the
peripherals it finds on the I-BUS.
CONTACT-ID only
If you select this option, the control panel will reset to default settings all the
event codes used for the CONTACT-ID reporting format.
DeletePrg.events
Press the
key to delete all the events saved to the control panel events log
(activation and restoral events):
•
All outputs
•
All calls
•
All options
WLS data reset
Press the
key to delete all the data relating to the Air2-BS100 device.
Note
The data relating to the wireless detectors and keyfobs will not reset on the control panel,
nor will the devices simulated by the Air2-BS100 transceiver be deleted from the
configuration.
3. The control panel will ask for confirmation of this command (press
).
CONTINUE?OK=YES
PROGRAMMING
Language
Messages
Default settings
Default settings
Factory data
Learn zone bal.
Auto enrolPeriph
Содержание GameOver SmartLiving 1050