72
Options and programming methods
Installation and Programming Manual
6-25
Other parameters
This option allows you to programme the advanced functions of the control panel.
Via Keypad
1. Access the “Other parameters” section.
Type-in Code
(Installer PIN)
, PROGRAMMING Other parameters
.
2. Use key
or
to select the parameter then press
.
Periodic event
This parameter allows you to set the time (hh/mm), day, month and year of the
first “Periodic event” (refer to paragraph
6-9 Events
).
Note
The time/date setting of this parameter must be later than the control panel clock setting.
PeriodicInterval
This parameter allows you to set the interval between “Periodic events”
(expressed in hours).
To disable the “Periodic event”, set “0”.
Mains fail.Delay
This parameter allows you to programme the delay, expressed in minutes (see
“info” box ), between mains failure and the “Mains failure” fault event signal.
LocKpadMessTimes
The number of times messages, relating to the events recorded on the keypad,
will be played (JOY/MAX keypads only).
The playback phase can be stopped by pressing any key. If you set a value of
“255” the playback can be stopped by pressing any key, this is the only method of
stopping playback.
OverThePhoneVol.
This is the volume of the voice messages over-the-phone.
Ring sensitivity
This value determines the reception sensitivity of incoming call rings. This option
is useful in situations of bad reception (break up) or noisy lines.
At default this value is set at 50. Accepted values: 1 to 100. The higher the value
the higher the sensitivity.
Wireless superv.
This value determines the wireless-detector supervision time. Once the pre-set
time expires, the detectors which do not respond will be signaled as lost.
Accepted values: 12 to 250 minutes.
Tel. input gain
This value determines the volume of the incoming call signal. This option is useful
in situations which require better comprehension of DTMF tones and
improvement of teleservice intervention via modem.
Adj. temperature
This parameter will allow you to enter the effective value of the room
temperature read by an external thermometer.. This value will replace the keypad
temperature reading and thus allow you to correct the temperature sensor on
the keypad you are working on (Joy/MAX only).
The entered value must be expressed in °C decimals (for example, type in 252 if
the temperature is 25.2 °C).
LowBattery delay
This parameter allows you to programme the delay, expressed in minutes, which
will be applied before “LowBattery” events are signaled.
LinedownDelay
This parameter allows you to programme the delay, expressed in seconds, which
will be applied before signaling of “LineDownDelay” events occurs.
All the above-mentioned parameters can be programmed as follows.
If this value is
expressed in minutes,
there is an error
margin of 1 minute (for
example, if you set 5 minutes,
the period can vary between 4
and 5 minutes).
OverThePhoneVol.
00_ Units
(Min. 010)
(Max. 100)
Tel. input gain
00_ Units
(Min. 001
(Max. 080)
If this value is
expressed in minutes,
there is an error
margin of 4 minutes (for
example, if you set 7 minutes,
the period can vary between 3
and 7 minutes).