Options and programming methods
Installation and Programming Manual
6-5
Terminals
This section describes the configuration flexibility of the system terminals. The
profile of each terminal can be configured as follows.
•
Programme the type of terminal:
••
Input (I)
••
Output (O)
••
Two way - supervised output (T)
••
Double Zone (D)
••
Unused (-)
•
Programme the parameters related to the selected configuration
ATTENTION!
For critical events or events of particular importance, it is advisable to use
keypad terminals T1 and T2 as the signal outputs. The status of these outputs
may switch (On to Off and vice versa) in the event of BUS reset.
50131StatHidden
The status of the partitions will be hidden.
If a valid
code is entered at a keypad, the real-time status will be
indicated on the keypad concerned for 30 seconds.
If the partitions are armed, the status of the system will be
hidden from non-authorized users.
•
Red keypad LED Off
•
Yellow keypad LED Off
•
Green keypad LED On solid
•
Status icons not present
•
Alarm and Tamper memory hidden
•
If a particular event occurs more than 5 times when
the partitions are armed, it will not be signaled as
having occurred more than 5 times. This is due to
the limitation placed on the counter of each event.
The counters will reset to zero each time all the
partitions are disarmed.
If the partitions are DISARMED:
•
The LEDs will function normally.
•
Status icons present
•
Alarm and Tamper memory visible
The keypad will show the real-time status
of the system at all times, regardless of
the status of its partitions.
50131IconsHidden
If partitions are armed, the status icons will be hidden from
non-authorized users.
If a valid code is entered at a keypad, the status of the icons
will be shown for 30 seconds.
The keypad will show the real-time status of the icons when all
the keypad partitions are disarmed.
The keypad will show the real-time status
of the icons at all times, regardless of the
status of its partitions.
50131AlarDelayed
If an instant-zone alarm occurs on a partition while entry time
is running, the associated actions (calls, output activation,
save to log, etc.) will not be generated until 30 seconds after
the expiry of the entry time.
If the partition (or partitions) are disarmed during this period,
the associated actions will not be generated, however, the
keypads will indicate the violation of the instant zone.
If an instant-zone alarm occurs on a
partition while entry time is running, the
associated actions (calls, output activation,
save to log, etc.) will be activated
instantly.
50131WarnLedMem
If the control panel detects a fault, the yellow LED on the
keypads will go On and will remain On even after the fault
clears.
To switch the yellow LED Off, clear all activating causes and
reset the partition.
If the control panel detects a fault, the
yellow LED on the keypads will go On and
will go Off automatically when the fault
clears.
DayLightSav.time
The control panel clock will go back automatically one hour at
03:00 last Sunday in October, and it will go forwards
automatically one hour at 02:00 last Sunday in March.
No automatic clock forward/back
operations.
NoStringsSiaProt
The descriptive strings will not be sent in SIA reporting format.
The descriptive strings will be sent in SIA
reporting format.
Nexus prior
Voice calls will be diverted to Nexus dialer.
Voice calls will be diverted to Nexus dialer
only when the PSTN line is down.
Invert CONTACT-ID
Partition arming events using CONTACT-ID reporting format
will send the "New event/Event activation" code when the
partition is armed and the "Event ended/Event restore" when
the partition is disarmed.
Partition arming events using CONTACT-ID
reporting format will send the "New event/
Event activation" code when the partition
is disarmed and the "Event ended/Event
restore" when the partition is armed.
Table 31:
Panel options
Option
If enabled
If disabled
Patent pending