46
Options and programming methods
Installation and Programming Manual
Select “SmartLiving System - Terminals” from the tree menu on the left, then go
to the “Parameters settings” template on the right:
All the terminals will be shown on the respective page. You must configure the
terminal graphically using the mouse, as follows:
1. Point to the terminal you require.
2. Right click on the mouse and select the required type.
3. Double click to set the options for the terminal.
4. Position the mouse on the programming field instead of on the specific ter-
minal to configure all the terminals in the same way.
If the terminal is configured as “Zone” (=INPUT) or “Double” (=DOUBLE ZONE),
it will appear in the Zone programming section (paragraph
6-6 Zones
). If the
terminal is configured as an “Outputs” (=OUTPUT) or “I/O” (= TWO WAY), it will
appear in the Outputs programming section (refer to paragraph
6-7 Zones
).
6-6
Zones
This programming section deals with all the zone parameters.
Via Keypad
1. Access the “Programming Zones” section.
Type-in Code
(Installer PIN)
, PROGRAMMING Zones
.
2. Use keys
and
to select the zone then press
.
Description
This is the editable label which identifies the zone. At default, all the zones
assume the description of the peripheral they refer to, followed by the respective
terminal.
1° riga:
default description
2° line:
current description
3° line:
description being edited
4° line:
letter/number selection
For example, the default description “Expansion 04 T03 corresponds to the zone
located on terminal T3 of Expansion n. 4. The default descriptions “Panel T05”
and “Panel T05D” correspond to the two zones located on terminal T5 of the
control panel, configured as “Double Zone”.
Partitions
These are the partitions the zone belongs to. A zone configured as “Automation”
cannot be assigned to any partition.
Use
and
to enable or disable the selected partition.
Type
Use
and
to select the type of zone, then press
. The available
Types are (refer to
Appendix A, Technical terminology and Glossary
):
•
Instant
•
Delayed
•
Delayed unhidden
•
Route
•
24 hour
•
Automation
•
Armed in Away mode
•
Disarm
•
Switch
•
OnArm/OffDisarm
•
Patrol
For “Arm”, “Disarm”, “Switch”, “OnArm/OffDisarm” “Follow” and “Patrol” zones,
refer to
Appendix A, Technical terminology and Glossary
,
Command Zones
.
“Delayed” and “Delayed unhidden” zones are delayed during entry and exit
phases, in accordance with the respective “Entry Time” and “Exit Time” settings
(refer to paragraph
6-11 Partitions
). A “Delayed unhidden” zone behave as
follows:
•• if violated when the system is disarmed, it will switch Off the blue LED on
the keypad
Office
Description
Partitions
Type
PROGRAMMING
Panel options
Terminals
Zones
PROGRAM ZONES
Office
Panel T02
Panel T03
Panel T01
Office
Board room
m oMNO6