Installation and Programming Manual
Options and programming methods
73
3. Use key
or
to select the field you wish to change, then use the
number keys (
, etc.) to edit the number.
or
Use key
or
to increase or decrease the number.
FaultNotReady
This section allows you to select which events, other than zones in alarm status,
will be signaled as system security-risk conditions when the partition arms.
Following are the events which can be enabled/disabled by means of keys
and :
•
Zone fuse fault
•
IBUS fuse fault
•
Low battery
•
Mains failure
•
Tel. line down
•
Jamming
•
Low battery WLS
•
WLS zone loss
•
LossTamp.ongoing
The last item groups the following events:
•• Panel opened
•• Dislodged panel
•• Expansion tamper
•• Keypad tamper
•• Reader tamper
•• Sound.flash.Tamp
•• Nexus tamper
•• Expansion loss
•• Keypad loss
•• Reader loss
•• Sound.flash.Loss
•• Nexus loss
4. Press
to confirm and exit.
Via PC
18:23 30/10/2011
EU dd/mm/yyyy
PROGRAMMING
Default settings
User functions
Other parameters
Other parameters
Periodic event
PeriodicInterval
Mains fail.Delay
Table 42:
Options - via SmartLeague software programme
Option
Part of the system
Template/section
Periodic event
SmartLiving System
Parameters settings - periodic event
PeriodicInterval
Mains fail.Delay
Parameters settings - I-BUS parameters
LocKpadMessTimes
Keypads
Parameters settings - Keypad parameters
OverThePhoneVol.
SmartLiving System
Parameters settings - Telephone options
Ring sensitivity
SmartLiving System - Telephone
Parameters settings - Telephone line
parameters
Wireless superv.
SmartLiving System
Parameters settings - Control panel
parameters
Tel. input gain
Parameters settings - Telephone options
LowBattery delay
Parameters settings - I-BUS parameters
LinedownDelay
SmartLiving System - Telephone
Parameters settings - Telephone dialer
parameters
FaultNotReady
SmartLiving System
Parameters settings - 50131 Parameters