ICON500 high performance vector control frequency inverter user
manual
Chapter 5 function code
table
- 88
-
ICON500 has two inbuilt counters:counter 1 is for 32 bit multifunctional counter with electronic gear;Counter 2
is a common counter with 16 bit without electronic gear.following is counter 1 function and use.
Counter 1 get input pulse signal via DI function 50 (counter 1 Input),when counter 1 comes to setting value
(P45.04) via electronic gear,it can come to signal via DO function (21) and counter will continue to count
When counter arrive maximum value,it will decide to overflow as per P45.13
Set Di(51) terminal to Count1 reset ,when terminal effective,counter 1 will reset
For example: P45.04
=
3, P45.08
=
3, P45.09
=
1,Count 1 functoin as following picture
Counter input:
Counter1 before
1 2 3 4 5 6 7 8 9
0
1 2 3 4
electronic gear
Counter1 after electronic
1
2
3
0
1
gear
Set value arrival output
Counteer reset DI input
r45.10
Counter 2(16 bit)
actual value
Read only and save when power off
-
●
P45.11
Counter 2 (16
bit) set value
1
~
65535
1000
☆
P45.12
Counter2 (16 bit)
maximum value
1
~
65535
65535
☆
P45.13
Counter 1/2
overflow action
0-stop;1-reset
00
~
11
Unit’digit
:
Count 1 overflow action
0: stop; 1:continue
Ten’digit
:
Count 1 overflow action
0: stop ; 1:continue
11
☆
Count 1/2 overflow action:when counter higher than maximum value as following chart
setting
4 5
6
4 5
6
4
Maximum
Counter
1 2
3
1 2
3
1 2
3
0
0
0
value
Pulse input
Stop counting
C o n t i n u e c o u n t i n g
after overflowing
60 Group Motor 2 basic parameter
P60.00
Control mode
Same as P00.04
0
★
P60.01
Upper limit
frequency
Same as P01.07
0
★
P60.02
Upper limit
frequency digital
setting
Lower limit (P01.09)
~
maximum
frequency(P01.06)
50.00Hz
☆
P60.04
Accel and Decel
time option
0
:
same as motor 1
1
:
Accel and Decel time 3
When choose 1,Motor 2 can convert
betweens accel and decal time 3 and 4 by DI
0
★