Chapter 5 Function code
table
ICON500 high performance vector control frequency inverter user
manual
-
27-
Make sure the power cable, motor cable and brake unit are connected
correctly
Follow the instructions in Chapter 3 to install the inverter and wire it
Enter guide mode
”
-GdE-
“
Observe the safety precautions and switch on the power supply
N
Open control
Y
close loop vector control(VC),Before normal
operation, ensure that the encoder P10.03 is in
the correct directionIf rotary self-learning is
performed, the encoder orientation can be
automatically recognized and storedIf it is not
executed, it needs to open the loop control to
run the motor and observe whether the encoder
feedback(r10.12) is in the same direction with
the given direction, if no,change as P10.03
Symbol
Meaning
tUnE
Motor parameter self-learning
bUSY
Processing parameter read and write requests
End
• Indicates that the parameters have been changed
and saved to the EEPROM
• The mission has been completed
Er.xxx
• Fault code, "XXX" is the fault type, see Chapter 6 for
details
Test run
Please follow the procedure below to commission the first power-on
。
Trial run flow chart
start
End
Press
“
RUN
”
to Run inverter
Press
“
STOP
”
to stop inverter
While monitoring the output frequency
or command frequency,press
“
ENTER
”
to modify the target frequency
Set each parameter in turn according to the
guidance of the wizard, set the motor self-
learning mode P11.10, press the run button,
waiting for the complete of self-learning