Chapter 5 Function code
table
ICON500 high performance vector control frequency inverter user
manual
-
71-
27 Group Monitoring parameter
r27.00
Running
frequency
It can set unit as per Parameter P21.07
-
●
r27.01
Set frequency
It can set unit as per Parameter P21.07
-
●
r27.02
Direction
indicator
bit0
:
direction of running frequency
bit1
:
direction of setting frequency
bit2
:
direction of main frequency
bit3
:
direction of auxiliary frequency
bit4
:
direction of UpDown offset
bit5 reserved
-
●
r27.03
Bus voltage
Unit
:
1V
-
●
r27.04
VF separation
setting
unit
:
0.1%
-
●
r27.05
Output voltage
unit
:
0.1V
-
●
r27.06
Output current
unit
:
0.1A
-
●
r27.07
Output current
percentage
unit
:
0.1%(100% of motor rated current)
-
●
r27.08
Output torque
0.1%
-
●
r27.09
Torque setting
0.1%
-
●
r27.10
Drives running
mode status 1
Bit0:Running status 0-Stop;1-Run
Bit1:Motor direction0-Forward;1-Reverse
Bit2:Ready signal:0-not ready;1-ready
Bit3:fault status 0-no fault;1-fault
Bit4
~
5:fault type:0-free stop;1-fast
stop;2-stop as per stop mode
;
3
:
continue to
run
Bit6:jog status:0-no jog;1-jog status
Bit7:Auto tune :0-no;1-yes
Bit8:DC braking:0-Non DC braking;1-DC
braking
Bit9:Reserved
Bit10
~
11:Acceleration and Deceleration:
0:stop/zero output;1:speed up;2:slow
down;3:constant speed
Bit12:reserved
Bit13:current limit status:0-no;1-yes
Bit14:overvoltage stalladjustment:0-no ;1-yes
Bit15:undervoltage stall
adjustment :0-no;1-yes
-
●
r27.11
Drives running
mode2
Bit0
~
1:current command
source:0-keypad;1-terminal ;2-communicatoi
n
Bit2
~
3:motor option:0-motor 1;1-motor 2
Bit4
~
5:current motor
control:0-VF;1-SVC;2-VC
-
●