Chapter 5 Function code
table
ICON500 high performance vector control frequency inverter user
manual
-
57-
14 Group Torque control
P14.00
Torque setting
0
:
digital setting
1
:
AI1
2
:
AI2
3
:
AI3(reserved)
4
:
AI4(reserved)
5
:
HDI
6
:
communication
0
★
P14.01
Torque digital setting
-200.0
~
200.0%
0
☆
P14.02
Maximum torque
Benchmark 10.0%
~
300.0%
Notice:torque benchmarks for analog inputs and
high frequency pulse input as well as limit
output torque in torque control
200.0%
★
P14.03
Torque Acceleration time
0.000s
~
60.000s
Notice:Torque given time from zero to motor
rated torque
0.100s
☆
P14.04
Torque control
Deceleration time
0.000s
~
60.000s
Notice:Torque given time from motor rated
torque to zero
0.100s
☆
P14.05
Upper limit frequency of
torque control
0
:
digital setting
1
:
AI1
2
:
AI2
3
:
AI3(expansion card)
4
:
AI4
(
expansion card
)
5
:
HDI high frequency pulse input
6
:
communication
0
★
P14.06
Upper limit frequency of
torque control
-100.0%
~
100.0%
100.0%
☆
P14.07
Reverse speed limit
Relative to maximum frequency
:
0.0%
~
100.0%
Notice:Speed limit for reverse speed direction
not specified by the speed limit source
40.0%
☆
P14.08
Torque setting over limit
speed
0
:
match torque setting
1
:
speed control
0
★
P14.10
Static friction torque
0.0%
~
50.0%
10.0%
☆
P14.11
Static friction torque
compensation
0.00Hz
~
50.00Hz
1.00Hz
★
P14.12
Dynamic friction factor
0.0%
~
50.0%
Dynamic friction at rated speed
Notice: motor sliding friction torque at rated
rotating speed
0.0%
☆
P14.13
Dynamic friction starting
value
0.0%
~
50.0%
0.0%
☆