10
IBM® xSeries 360: User’s Reference
2.
Disconnect the server power cords from the power source.
Note:
Wait approximately 15 seconds after disconnecting the power cords for the
server to stop running. The power LED on the operator information panel
will stop blinking.
Standby mode
Standby mode refers to the condition in which the server operating system is not
running and all core logic is shut down except for the Remote Supervisor Adapter.
Complete the following steps to put the server into standby mode:
1.
See the operating system documentation for the proper procedure to shut down
the operating system.
Note:
Each operating system is different. Read all the documentation about
shutting down the operating system before continuing.
2.
Press the power-control button on the front of the server.
You can put the server into standby mode remotely by means of the Remote
Supervisor Adapter.