32
IBM® xSeries 360: User’s Reference
13. If you also want to configure the serial port, continue with “Configuring the serial
port for text-based remote access”. Otherwise, go to “Installing Advanced System
Management device drivers” on page 35.
Configuring the serial port for text-based remote access:
Complete the following
steps to configure the Remote Supervisor Adapter serial port for access using a
modem or null modem. If you completed the procedure for configuring the Ethernet
port and the Configuration Settings window is open, go to step 4.
1.
With the server turned off, insert the diskette with the downloaded utility program
into the diskette drive; then, turn on the server.
2.
The utility starts automatically, displaying the Remote Supervisor Utility window.
3.
Use the Up Arrow and Down Arrow keys (
↑
and
↓
) to select
Configuration
Settings
; then, press Enter.
The Configuration Settings window opens.
4.
Use the arrow keys to select
Modem Settings
; then, press Enter.
The Modem Settings window opens, as shown in the following illustration.
Note:
The values in the window are only examples; your settings might be
different.
5.
Verify the following serial port values:
Baud Rate
The default is 57600. Make sure that the baud rate matches the baud
rate of the device you are connecting to the serial port on the Remote
Supervisor Adapter.
Dedicated to ASM
The default is Disabled. If you are using point-to-point protocol (PPP), set
this field to Enabled. If the value in this field is Enabled when the server is
restarted, the serial port remains dedicated to system management and
is not returned to the operating system.
You can dedicate the integrated serial port on the Remote Supervisor
Adapter to system management or share it with the operating system. If
the serial port is dedicated to system management, it serves only the
Remote Supervisor Adapter and is always available for dial-in or dial-out
alerting purposes. You cannot view the port using the operating system
or any application.
Содержание Eserver xSeries 360 Type 8686
Страница 1: ...User s Reference xSeries 360 Type 8686...
Страница 2: ......
Страница 3: ...IBM IBM xSeries 360 User s Reference...
Страница 8: ...vi IBM xSeries 360 User s Reference...
Страница 14: ...xii IBM xSeries 360 User s Reference...
Страница 64: ...50 IBM xSeries 360 User s Reference...
Страница 108: ...94 IBM xSeries 360 User s Reference...
Страница 162: ...148 IBM xSeries 360 User s Reference...
Страница 183: ......
Страница 184: ...IBM Part Number 24P2866 Printed in the United States of America 24P2866...