136
IBM® xSeries 360: User’s Reference
Ethernet controller messages
The integrated Ethernet controller might display messages from the following device
drivers:
•
Novell NetWare or IntraNetWare system open data-link interface (ODI)
•
Network driver interface specification (NDIS) adapter for Windows NT or Windows
2000
Novell NetWare or IntraNetWare system ODI driver messages
This section provides explanations of the error messages for the Novell NetWare or
IntraNetWare system ODI driver, and suggested actions to resolve each problem.
The Ethernet controller
stopped working without
apparent cause.
Check the following:
•
Run diagnostics for the Ethernet controller.
•
Try a different connector on the hub.
•
Reinstall the device drivers. Refer to the operating system documentation and to
the ServerGuide information.
If the problem remains, call for service.
Table 17. Ethernet troubleshooting chart.
Ethernet controller
problems
Suggested action
Table 18. NetWare or IntraNetWare system ODI driver teaming messages for the Ethernet controller.
Message
Description
Couldn’t allocate resources.
Explanation:
An unknown error has occurred when trying to allocate needed
resources for the AFT Module.
Action:
•
Check the system configuration. If the problem remains, contact the
network supplier.
•
Verify that the Ethernet controller is enabled. If the Ethernet controller is
enabled, run the diagnostic programs.
AFT group for primary adapter in slot
nnn
already exists.
Explanation:
An attempt was made to rebind an adapter already in an AFT
group.
Action:
Check the AFT slot numbers for existing AFT teams. If the problem
remains, contact the network supplier.
Error locating device control table
(DCT) addresses in internal table.
Make sure that you have loaded LAN
drivers after loading AFT.NLM.
Explanation:
The bind command was entered prior to loading the device
driver. The device driver must be loaded after loading AFT.NLM, but before any
bind command can be issued.
Action:
Load the driver for the supported adapter and try loading the AFT
module again. If the problem remains, contact the network supplier.
Insufficient number of arguments
specified.
Explanation:
The appropriate or expected number of parameters was not
entered in a command.
Action:
Check the parameters required for the given command. If the problem
remains, contact the network supplier.
Содержание Eserver xSeries 360 Type 8686
Страница 1: ...User s Reference xSeries 360 Type 8686...
Страница 2: ......
Страница 3: ...IBM IBM xSeries 360 User s Reference...
Страница 8: ...vi IBM xSeries 360 User s Reference...
Страница 14: ...xii IBM xSeries 360 User s Reference...
Страница 64: ...50 IBM xSeries 360 User s Reference...
Страница 108: ...94 IBM xSeries 360 User s Reference...
Страница 162: ...148 IBM xSeries 360 User s Reference...
Страница 183: ......
Страница 184: ...IBM Part Number 24P2866 Printed in the United States of America 24P2866...