Chapter 6. Solving Problems
105
11
xx
An error occurred during the system-board serial port test.
Action:
If you have a modem, serial printer, or other serial device
attached to the server, verify that the serial cable is connected
correctly. If it is, use the following procedure:
1.
Turn off the server.
2.
Disconnect the serial cable from the serial port.
3.
Wait 5 seconds; then, turn on the server.
If the POST error message does not reappear, either the serial cable or
the device is probably failing. See the documentation that comes with the
serial device for additional testing information.
If the POST error message reappears, call for service.
1162
The serial port configuration conflicts with another device in the system.
Action:
1.
Make sure the IRQ and I/O port assignments needed by the
serial port are available.
2.
If all interrupts are being used by adapters, you might need
to remove an adapter to make an interrupt available to the
serial port, or force other adapters to share an interrupt.
1301
Cable to the operator information panel not detected.
Action:
Make sure that the cable to the operator information panel card is
connected.
If the problem remains, call for service.
1302
Cable to SCSI Backplane not detected.
Action:
Make sure that the cable between the Level 2 Light Path card and
the SCSI hard drive back plane is connected.
If the problem remains, call for service.
1303
Cable to Hotplug Switch not detected.
Action:
Make sure that the cable between the PCI switch card and the
system board (J36) is connected.
If the problem remains, call for service.
1304
Cable to Media not detected.
Action:
Make sure that the cable between the media interposer card and
the Level 2 Light Path card is connected.
If the problem remains, call for service.
1600
The Remote Supervisor Adapter is not functioning.
Action:
1.
Verify that the jumpers for the Remote Supervisor Adapter
are set correctly.
2.
Disconnect the server from all electrical sources, wait for 30
seconds, reconnect the server to the electrical sources, and
restart the server.
If the problem remains, call for service.
1162
The serial port configuration conflicts with another device in the server.
Start the Configuration/Setup Utility program and ensure that the IRQ and
I/O port assignments needed by the serial port are available.
Table 12. POST error messages.
POST message
Description
Содержание Eserver xSeries 360 Type 8686
Страница 1: ...User s Reference xSeries 360 Type 8686...
Страница 2: ......
Страница 3: ...IBM IBM xSeries 360 User s Reference...
Страница 8: ...vi IBM xSeries 360 User s Reference...
Страница 14: ...xii IBM xSeries 360 User s Reference...
Страница 64: ...50 IBM xSeries 360 User s Reference...
Страница 108: ...94 IBM xSeries 360 User s Reference...
Страница 162: ...148 IBM xSeries 360 User s Reference...
Страница 183: ......
Страница 184: ...IBM Part Number 24P2866 Printed in the United States of America 24P2866...