![IBM 8645 - Eserver xSeries 220 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/ibm/8645-eserver-xseries-220/8645-eserver-xseries-220_hardware-maintenance-manual_3742786033.webp)
Table 5. NDIS (Windows NT or Windows 2000) driver messages for the Ethernet
controller (continued)
Error code
(hex)
Description
0x02
Explanation:
Bad node address (multicast address).
Action:
Make sure the
locally administered address is valid, if one is specified. The address can
not be a multicast address.
0x03
Explanation:
Failed self-test.
Action:
Make sure a cable is attached to the
Ethernet connector. If the problem persists, call for service.
0x0D
Explanation:
Could not allocate enough memory for transmit queues.
Action:
1.
From the Windows NT desktop, select
Start -> Control Panel ->
Networks -> Adapters
.
2.
Select your IBM Ethernet adapter from the list.
3.
Select
Properties -> Advanced
.
4.
Lower the resource values that apply to the transmit queue.
0x0E
Explanation:
Could not allocate enough memory for receive queue.
Action:
1.
From the Windows NT desktop, selec
t Start -> Control Panel ->
Networks -> Adapter
s.
2.
Select your IBM Ethernet adapter from the list.
3.
Select
Properties -> Advanced
.
4.
Lower the resource values that apply to the receive queue.
0x0F
Explanation:
Could not allocate enough memory for other structures.
Action:
1.
From the Windows NT desktop, select
Start -> Control Panel ->
Networks -> Adapters
.
2.
Select your IBM Ethernet adapter from the list.
3.
Select
Properties -> Advanced
.
4.
Lower the value for the resource named in the message.
0x10
Explanation:
Did not find any Ethernet controllers.
Action:
Using the
Configuration/Setup Utility, make sure that Ethernet is enabled.
0x11
Explanation:
Multiple Ethernet controllers found, but none matched the
required ID.
Action:
Using the Configuration/Setup Utility, make sure that
Ethernet is enabled.
0x13
Explanation:
Did not find any Ethernet controllers that matched the
required subven/subdev.
Action:
Using the Configuration/Setup Utility,
make sure that Ethernet is enabled.
0x16
Explanation:
Single adapter found but multiple instances tried to load.
Action:
Using the Configuration/Setup Utility, make sure that Ethernet is
enabled, and that the slot containing the IBM 10/100 Ethernet Adapter or
the IBM 10/100 EtherJet
™
PCI adapter is enabled.
0x17
Explanation:
Slot parameter not specified in the registry.
Action:
Remove
the adapter driver and reinstall it. If the problem persists, call for service.
All other
4-character
hexadecimal
codes
Action:
Call for service.
Diagnostics
25
Содержание 8645 - Eserver xSeries 220
Страница 1: ...Hardware Maintenance Manual xSeries 220 Type 8645...
Страница 2: ......
Страница 3: ...Hardware Maintenance Manual xSeries 220 Type 8645...
Страница 18: ...10 Hardware Maintenance Manual xSeries 220 Type 8645...
Страница 36: ...28 Hardware Maintenance Manual xSeries 220 Type 8645...
Страница 58: ...50 Hardware Maintenance Manual xSeries 220 Type 8645...
Страница 102: ...94 Hardware Maintenance Manual xSeries 220 Type 8645...
Страница 141: ...Related service information 133...
Страница 142: ...134 Hardware Maintenance Manual xSeries 220 Type 8645...
Страница 143: ...Related service information 135...
Страница 144: ...136 Hardware Maintenance Manual xSeries 220 Type 8645...
Страница 145: ...Related service information 137...
Страница 146: ...138 Hardware Maintenance Manual xSeries 220 Type 8645...
Страница 147: ...Related service information 139...
Страница 148: ...140 Hardware Maintenance Manual xSeries 220 Type 8645...
Страница 158: ...150 Hardware Maintenance Manual xSeries 220 Type 8645...
Страница 159: ...Related service information 151...
Страница 160: ...152 Hardware Maintenance Manual xSeries 220 Type 8645...
Страница 167: ......