PCNTW-DOS-5 PCNTNW MLID could not be unloaded;
the operation was aborted.
Explanation: The PCNTNW MLID attempted to remove
the resident PCNTNW MLID from memory, and failed. A
hardware error has probably occurred.
Action: Run the Ethernet diagnostic.
PCNTW-DOS-6 The adapter did not initialize. PCNTNW
did not unload.
Explanation: The hardware did not initialize correctly.
The PCNTNW driver did not load.
Action: Check the hardware. Make sure that the board's
hardware setting matches its settings in the NET.CFG file.
PCNTW-DOS-7 You need another PCNTNW MLID
Section Heading in the NET.CFG file in
order to load the MLID again.
Explanation: You tried to load the PCNTNW MLID a
second time. Normally, you would do this so that you
could use two or more Ethernet controllers in the server.
When two or more of the same type of Ethernet controllers
are installed in the server, an associated PCNTNW MLID
section heading must be specified in the NET.CFG file.
Action: Create a NET.CFG file and add the commands
for both PCNTNW MLID boards to the file. Then, restart
the server.
PCNTNW-DOS-8 A NET.CFG is required to load the
MLID again.
Explanation: You tried to load the PCNTNW MLID a
second time. Normally, you would do this so that you
could use two or more Ethernet controllers in the server.
When two or more of the same type of Ethernet controllers
are installed in the server, an associated PCNTNW MLID
section heading must be specified in the NET.CFG file.
Action: Create a NET.CFG file and add the commands
for both PCNTNW MLID boards to the file. Then, restart
the server.
PCNTNW-DOS-9 The NET.CFG entry has been ignored.
Explanation: The PCNTNW ignored the NET.CFG entry.
Action: Verify that the entries in the NET.CFG file are
correct.
The PCNTNW MLID has been successfully removed.
Explanation: A request was made to unload a PCNTNW
MLID. The PCNTNW MLID has been removed from
memory.
Action: None.
34
PC Server HMM
Содержание 315
Страница 89: ...Expansion Slot Cover Expansion slot Cover Expansion slot Screw Floor Stand PC Server 315 Type 8638 85...
Страница 90: ...Identification Numbers Serial Number Machine Type Model 86 PC Server HMM...
Страница 92: ...Bay 3 3 5 Inch Drive 88 PC Server HMM...
Страница 93: ...Bay 3 5 25 Inch Drive PC Server 315 Type 8638 89...
Страница 103: ...U Bolt PC Server 315 Type 8638 99...
Страница 130: ...Parts Listings PC Server 315 Type 8638 System 1 2 3 4 5 6 7 8 9 10 11 12 13 126 PC Server HMM...
Страница 151: ...IBM Part Number 84H7201 Printed in U S A S84H 72 1...