Error Code
FRU/Action
1962
Boot sequence error.
1. Possible hard disk
drive problem, see
“Hard Disk Drive
Boot Error” on
page 56.
209X
1. Diskette Drive
2. Diskette Cable
3. 16-bit AT Fast SCSI
Adapter
20XX
Not listed above
1. BSC Adapter
2. Riser Card
21XX
1. SCSI Device
2. 16-bit AT Fast SCSI
Adapter
3. Alternate BSC Adapter
4. Riser Card
2401, 2402
If screen colors change.
1. Display
2401, 2402
If screen colors are OK.
1. System Board
2. Display
2409
1. Display
2410
1. System Board
2. Display
2462
Video memory configuration
error.
1. Check cable
connections.
2. Run Setup and verify
video configuration
settings.
3. Video Memory
Modules
4. Video Adapter
(if installed)
5. System Board
3015, 3040
Check for missing wrap
or terminator plug on the
adapter.
1. Network Attached?
2. LF Translator
3. Cable Problem
4. PC Network Adapter
5. Riser Card
30XX
1. PC Network Adapter
2. LF Translator
3. Cable Problem?
4. Riser Card
3115, 3140
1. Network Attached?
2. LF Translator
3. Alternate PC
Network-Adapter
4. Cable Problem
5. Riser Card
31XX
1. Alternate PC Network
Adapter
2. LF Translator
3. Cable Problem?
4. Riser Card
PC Server 315 - Type 8638
109
Содержание 315
Страница 89: ...Expansion Slot Cover Expansion slot Cover Expansion slot Screw Floor Stand PC Server 315 Type 8638 85...
Страница 90: ...Identification Numbers Serial Number Machine Type Model 86 PC Server HMM...
Страница 92: ...Bay 3 3 5 Inch Drive 88 PC Server HMM...
Страница 93: ...Bay 3 5 25 Inch Drive PC Server 315 Type 8638 89...
Страница 103: ...U Bolt PC Server 315 Type 8638 99...
Страница 130: ...Parts Listings PC Server 315 Type 8638 System 1 2 3 4 5 6 7 8 9 10 11 12 13 126 PC Server HMM...
Страница 151: ...IBM Part Number 84H7201 Printed in U S A S84H 72 1...