Note
It is CRUCIAL to set the Active Time, otherwise Intelli-Guard™ will not work.
11. Click Save to save the selected area configurations
IMPORTANT: Ensure there is NO MOTION occurring in the defined area when clicking
Save, otherwise the Intelli-Guard™ function will not work properly for that area. The
reason for this is that the Intelli-Guard™ does not detect motion itself, but changes in
the pixels that make up an image. When Save is clicked, Intelli-Guard™ registers the
current image as the default image. All consequent changes to that area will be registered.
If motion occurs in the defined area when the Save is clicked, even the static environment
will set off the alarm.
12. To delete one defined target zone, select the area by clicking on it, hold down the left
mouse button and drag the area to remove it from the live view screen.
13. To delete all defined target zones, click Reset
14. To delete all defined target zones and select the entire camera view for motion monitoring,
click Reset & Add All
Count target zone (Gate) configurations
Each target zone has its own configuration and has to be saved individually. The Gate menu
specifies which target zone is currently selected. The Count target zone not only detects the
motion, but also detects the direction of the motion. The Count target zone is shown as a green
arrow with a red number in the middle. The number signifies the amount of detected motions
moving in this direction. To switch between the target zones, click the desired target zone arrow
in the live view screen.
1.
Define the target zones in the live view screen on the left. Up to 3 target zones (Gates)
can be configured.
a.
Place the mouse cursor at the start point over the live-mode camera view on the
left
b.
Hold down the left mouse button and drag the cursor to draw the rectangular target
zone
c.
Let the mouse button go
75