Active Time
Active Time refers to the designated time when the control is active (is on). The default setting
is 00:00-00:00, which means the control is always off. The control will be continuously on, if the
Active Time is set to 00:00 - 24:00. During the Active Time, the control cannot be turned off from
the main screen. Outside of the Active Time, the control can be activated by sensor, or manually
from the main screen.
Dwell Time
Dwell Time is the time that the control will stay turned on when it is sensor-triggered. This does
not apply if the control is turned on manually from the main screen. In other words, if the control
is turned on manually from the main screen, it will stay on until manually disabled by the user.
Dwell time also does not apply during the Active Time, when the control is continuously on.
Creating or Modifying Control Settings
To configure the available controls, do the following:
1.
Check the Enable checkbox for all installed controls
2.
Give each control a descriptive Name.
3.
Set the Active Time for each control if required. In the above example, Control 1 (Open
the Door) is always off; Control 2 (Turn on the Light) is continuously on between 8:30
AM and 5 PM.
4.
Associate the controls with the desired Sensors. If a selected sensor is triggered outside
of the Control Active Time, the specific control is activated. In the above example, if
Sensor 1 is triggered, Control 1 (Open the Door) will be activated. If the Sensor 3 is
triggered, Control 2 will be activated.
5.
Enter the Dwell (Sec) time for the control. In the above example, Control 1 (Open the
Door) will stay on for 5 seconds if Sensor 1 is triggered. Control 2 (Turn on the Light)
will stay on for 10 seconds if Sensor 3 is triggered outside of the Active Time.
Related Topics: Sensor Setup | Motion Detection | System Setup | E-Map Setup | Intelli-Guard™
| Intelli-Zone™ | VideoLogix™
Hardware Setup - External Monitor Setup
Overview
The External Monitor section allows the user to view specified cameras on an external monitor.
Cameras are displayed one-by-one in a sequence with a delay equal to the dwell time.
Dwell (Sec)
19
i³Server
XML to PDF by RenderX XEP XSL-FO Formatter, visit us at